All issues
- 2024 Vol. 16
- 2023 Vol. 15
- 2022 Vol. 14
- 2021 Vol. 13
- 2020 Vol. 12
- 2019 Vol. 11
- 2018 Vol. 10
- 2017 Vol. 9
- 2016 Vol. 8
- 2015 Vol. 7
- 2014 Vol. 6
- 2013 Vol. 5
- 2012 Vol. 4
- 2011 Vol. 3
- 2010 Vol. 2
- 2009 Vol. 1
-
Computer aided analysis of medical image recognition for example of scintigraphy
Computer Research and Modeling, 2016, v. 8, no. 3, pp. 541-548Views (last year): 3. Citations: 3 (RSCI).The practical application of nuclear medicine demonstrates the continued information deficiency of the algorithms and programs that provide visualization and analysis of medical images. The aim of the study was to determine the principles of optimizing the processing of planar osteostsintigraphy on the basis of сomputer aided diagnosis (CAD) for analysis of texture descriptions of images of metastatic zones on planar scintigrams of skeleton. A computer-aided diagnosis system for analysis of skeletal metastases based on planar scintigraphy data has been developed. This system includes skeleton image segmentation, calculation of textural, histogram and morphometrical parameters and the creation of a training set. For study of metastatic images’ textural characteristics on planar scintigrams of skeleton was developed the computer program of automatic analysis of skeletal metastases is used from data of planar scintigraphy. Also expert evaluation was used to distinguishing ‘pathological’ (metastatic) from ‘physiological’ (non-metastatic) radiopharmaceutical hyperfixation zones in which Haralick’s textural features were determined: autocorrelation, contrast, ‘forth moment’ and heterogeneity. This program was established on the principles of сomputer aided diagnosis researches planar scintigrams of skeletal patients with metastatic breast cancer hearths hyperfixation of radiopharmaceuticals were identified. Calculated parameters were made such as brightness, smoothness, the third moment of brightness, brightness uniformity, entropy brightness. It has been established that in most areas of the skeleton of histogram values of parameters in pathologic hyperfixation of radiopharmaceuticals predominate over the same values in the physiological. Most often pathological hyperfixation of radiopharmaceuticals as the front and rear fixed scintigramms prevalence of brightness and smoothness of the image brightness in comparison with those of the physiological hyperfixation of radiopharmaceuticals. Separate figures histogram analysis can be used in specifying the diagnosis of metastases in the mathematical modeling and interpretation bone scintigraphy. Separate figures histogram analysis can be used in specifying the diagnosis of metastases in the mathematical modeling and interpretation bone scintigraphy.
-
Mathematical modeling the kinetics and calculation of dosimetric characteristics of osteotropic radiopharmaceutical drugs
Computer Research and Modeling, 2022, v. 14, no. 3, pp. 647-660In Russian medicine two radiopharmaceuticals are currently used for radionuclide therapy of bone metastases: 89Sr-chloride and 153Sm-oxabifor. The first one has many side effects, so its use is limited. The second one is available only in clinics, its transportation to which does not take much time. Currently, the third radiopharmaceutical 188Re-solerene is undergoing clinical trials. Due to the generator method of obtaining 188Re, this radiopharmaceutical should become available for use in many regions of our country. Therefore, there is a need for a comparative analysis of the characteristics of these radiopharmaceuticals, including on the basis of mathematical modeling.
The article discusses the features of mathematical modeling the kinetics of osteotropic radiopharmaceutical drugs in the human body with bone metastases. Based on the four-compartment model, a complex of modeling and calculation of pharmacokinetic and dosimetric characteristics of radiopharmaceuticals for radionuclide therapy of bone metastases was developed and tested. Using clinical data, the transport constants of the model were identified and the individual characteristics of Russian radiopharmaceuticals labeled 89Sr, 153Sm and 188Re were calculated (effective half-lives, maximum activity in the compartments and the times of their achievement, absorbed doses to bone tissue and metastases, endosteal bone layer, red bone marrow, blood, kidneys and bladder). The time activity dependencies for all compartments of the model are obtained and analyzed. A comparative analysis of the pharmacokinetics and dosimetry of three radiopharmaceuticals (89Sr-chloride, 153Sm-oxabiphore, 188Re-solerene) was carried out.
From a comparative analysis of the pharmacokinetic and dosimetric characteristics of these radiopharmaceutical drugs, it follows that the best of them for widespread use in many regions of our country should be 188Re-solerene, taking into account the generator method of obtaining 188Re in a hospital.
-
Modeling the kinetics of radiopharmaceuticals with iodine isotopes in nuclear medicine problems
Computer Research and Modeling, 2020, v. 12, no. 4, pp. 883-905Radiopharmaceuticals with iodine radioisotopes are now widely used in imaging and non-imaging methods of nuclear medicine. When evaluating the results of radionuclide studies of the structural and functional state of organs and tissues, parallel modeling of the kinetics of radiopharmaceuticals in the body plays an important role. The complexity of such modeling lies in two opposite aspects. On the one hand, excessive simplification of the anatomical and physiological characteristics of the organism when splitting it to the compartments that may result in the loss or distortion of important clinical diagnosis information, on the other – excessive, taking into account all possible interdependencies of the functioning of the organs and systems that, on the contrary, will lead to excess amount of absolutely useless for clinical interpretation of the data or the mathematical model becomes even more intractable. Our work develops a unified approach to the construction of mathematical models of the kinetics of radiopharmaceuticals with iodine isotopes in the human body during diagnostic and therapeutic procedures of nuclear medicine. Based on this approach, three- and four-compartment pharmacokinetic models were developed and corresponding calculation programs were created in the C++ programming language for processing and evaluating the results of radionuclide diagnostics and therapy. Various methods for identifying model parameters based on quantitative data from radionuclide studies of the functional state of vital organs are proposed. The results of pharmacokinetic modeling for radionuclide diagnostics of the liver, kidney, and thyroid using iodine-containing radiopharmaceuticals are presented and analyzed. Using clinical and diagnostic data, individual pharmacokinetic parameters of transport of different radiopharmaceuticals in the body (transport constants, half-life periods, maximum activity in the organ and the time of its achievement) were determined. It is shown that the pharmacokinetic characteristics for each patient are strictly individual and cannot be described by averaged kinetic parameters. Within the framework of three pharmacokinetic models, “Activity–time” relationships were obtained and analyzed for different organs and tissues, including for tissues in which the activity of a radiopharmaceutical is impossible or difficult to measure by clinical methods. Also discussed are the features and the results of simulation and dosimetric planning of radioiodine therapy of the thyroid gland. It is shown that the values of absorbed radiation doses are very sensitive to the kinetic parameters of the compartment model. Therefore, special attention should be paid to obtaining accurate quantitative data from ultrasound and thyroid radiometry and identifying simulation parameters based on them. The work is based on the principles and methods of pharmacokinetics. For the numerical solution of systems of differential equations of the pharmacokinetic models we used Runge–Kutta methods and Rosenbrock method. The Hooke–Jeeves method was used to find the minimum of a function of several variables when identifying modeling parameters.
Indexed in Scopus
Full-text version of the journal is also available on the web site of the scientific electronic library eLIBRARY.RU
The journal is included in the Russian Science Citation Index
The journal is included in the RSCI
International Interdisciplinary Conference "Mathematics. Computing. Education"