Numerical simulation of fluid flow in a blood pump in the FlowVision software package
Computer Research and Modeling, 2023, v. 15, no. 4, pp. 1025-1038A numerical simulation of fluid flow in a blood pump was performed using the FlowVision software package. This test problem, provided by the Center for Devices and Radiological Health of the US. Food and Drug Administration, involved considering fluid flow according to several design modes. At the same time for each case of calculation a certain value of liquid flow rate and rotor speed was set. Necessary data for calculations in the form of exact geometry, flow conditions and fluid characteristics were provided to all research participants, who used different software packages for modeling. Numerical simulations were performed in FlowVision for six calculation modes with the Newtonian fluid and standard $k-\varepsilon$ turbulence model, in addition, the fifth mode with the $k-\omega$ SST turbulence model and with the Caro rheological fluid model were performed. In the first stage of the numerical simulation, the convergence over the mesh was investigated, on the basis of which a final mesh with a number of cells of the order of 6 million was chosen. Due to the large number of cells, in order to accelerate the study, part of the calculations was performed on the Lomonosov-2 cluster. As a result of numerical simulation, we obtained and analyzed values of pressure difference between inlet and outlet of the pump, velocity between rotor blades and in the area of diffuser, and also, we carried out visualization of velocity distribution in certain cross-sections. For all design modes there was compared the pressure difference received numerically with the experimental data, and for the fifth calculation mode there was also compared with the experiment by speed distribution between rotor blades and in the area of diffuser. Data analysis has shown good correlation of calculation results in FlowVision with experimental results and numerical simulation in other software packages. The results obtained in FlowVision for solving the US FDA test suggest that FlowVision software package can be used for solving a wide range of hemodynamic problems.
-
Reduced mathematical model of blood coagulation taking into account thrombin activity switching as a basis for estimation of hemodynamic effects and its implementation in FlowVision package
Computer Research and Modeling, 2023, v. 15, no. 4, pp. 1039-1067The possibility of numerical 3D simulation of thrombi formation is considered.
The developed up to now detailed mathematical models describing formation of thrombi and clots include a great number of equations. Being implemented in a CFD code, the detailed mathematical models require essential computer resources for simulation of the thrombi growth in a blood flow. A reasonable alternative way is using reduced mathematical models. Two models based on the reduced mathematical model for the thrombin generation are described in the given paper.
The first model describes growth of a thrombus in a great vessel (artery). The artery flows are essentially unsteady. They are characterized by pulse waves. The blood velocity here is high compared to that in the vein tree. The reduced model for the thrombin generation and the thrombus growth in an artery is relatively simple. The processes accompanying the thrombin generation in arteries are well described by the zero-order approximation.
A vein flow is characterized lower velocity value, lower gradients, and lower shear stresses. In order to simulate the thrombin generation in veins, a more complex system of equations has to be solved. The model must allow for all the non-linear terms in the right-hand sides of the equations.
The simulation is carried out in the industrial software FlowVision.
The performed numerical investigations have shown the suitability of the reduced models for simulation of thrombin generation and thrombus growth. The calculations demonstrate formation of the recirculation zone behind a thrombus. The concentration of thrombin and the mass fraction of activated platelets are maximum here. Formation of such a zone causes slow growth of the thrombus downstream. At the upwind part of the thrombus, the concentration of activated platelets is low, and the upstream thrombus growth is negligible.
When the blood flow variation during a hart cycle is taken into account, the thrombus growth proceeds substantially slower compared to the results obtained under the assumption of constant (averaged over a hard cycle) conditions. Thrombin and activated platelets produced during diastole are quickly carried away by the blood flow during systole. Account of non-Newtonian rheology of blood noticeably affects the results.