Результаты поиска по 'aorta':
Найдено статей: 4
  1. Ovcharenko E.A., Klyshnikov K.U., Savrasov G.V., Nyshtaev D.V., Glushkova T.V.
    The choosing of optimal cell parameters of transcatheter aortic valve prosthesis
    Computer Research and Modeling, 2014, v. 6, no. 6, pp. 943-954

    This paper presents the analysis of dependences between frame basic cell geometry parameters and function via finite element analysis. The simplified models of frame cell with varied strut width, thickness and quantity in a circle was researched to evaluate radial forces, maximum stress and strain, permanent residual strain and pinching load forces. The outcomes of this study might help in the development of new artificial heart valves and during the analysis of existing in-clinical TAVI prostheses.

    Views (last year): 1. Citations: 1 (RSCI).
  2. Tregubov V.P.
    Mathematical modelling of the non-Newtonian blood flow in the aortic arc
    Computer Research and Modeling, 2017, v. 9, no. 2, pp. 259-269

    The purpose of research was to develop a mathematical model for pulsating blood flow in the part of aorta with their branches. Since the deformation of this most solid part of the aorta is small during the passage of the pulse wave, the blood vessels were considered as non-deformable curved cylinders. The article describes the internal structure of blood and some internal structural effects. This analysis shows that the blood, which is essentially a suspension, can only be regarded as a non-Newtonian fluid. In addition, the blood can be considered as a liquid only in the blood vessels, diameter of which is much higher than the characteristic size of blood cells and their aggregate formations. As a non-Newtonian fluid the viscous liquid with the power law of the relationship of stress with shift velocity was chosen. This law can describe the behaviour not only of liquids but also dispersions. When setting the boundary conditions at the entrance into aorta, reflecting the pulsating nature of the flow of blood, it was decided not to restrict the assignment of the total blood flow, which makes no assumptions about the spatial velocity distribution in a cross section. In this regard, it was proposed to model the surface envelope of this spatial distribution by a part of a paraboloid of rotation with a fixed base radius and height, which varies in time from zero to maximum speed value. The special attention was paid to the interaction of blood with the walls of the vessels. Having regard to the nature of this interaction, the so-called semi-slip condition was formulated as the boundary condition. At the outer ends of the aorta and its branches the amounts of pressure were given. To perform calculations the tetrahedral computer network for geometric model of the aorta with branches has been built. The total number of meshes is 9810. The calculations were performed with use of the software package ABACUS, which has also powerful tools for creating geometry of the model and visualization of calculations. The result is a distribution of velocities and pressure at each time step. In areas of branching vessels was discovered temporary presence of eddies and reverse currents. They were born via 0.47 s from the beginning of the pulse cycle and disappeared after 0.14 s.

    Views (last year): 13.
  3. Ovcharenko E.A., Klyshnikov K.U., Savrasov G.V., Nyshtaev D.V., Kudryavtseva Y.A.
    Choice of design of transcatheter aortic valve prosthesis frame based on finite element analysis
    Computer Research and Modeling, 2015, v. 7, no. 4, pp. 909-922

    This article presents an analysis of the impact of the transcatheter prosthesis frame design features on the results of its implantation in the aortic root model. In this paper we analyzed the various approaches to the design of such structures, as well as modifications in order to improve their functional characteristics during the implantation. As a general method for obtaining the results of interaction of the objects was used finite element method with nonlinear materials description and analysis of the main parameters: the stress-strain state, radial and friction forces.

    Views (last year): 3. Citations: 1 (RSCI).
  4. Ameenuddin M., Anand M.
    CFD analysis of hemodynamics in idealized abdominal aorta-renal artery junction: preliminary study to locate atherosclerotic plaque
    Computer Research and Modeling, 2019, v. 11, no. 4, pp. 695-706

    Atherosclerotic diseases such as carotid artery diseases (CAD) and chronic kidney diseases (CKD) are the major causes of death worldwide. The onset of these atherosclerotic diseases in the arteries are governed by complex blood flow dynamics and hemodynamic parameters. Atherosclerosis in renal arteries leads to reduction in arterial efficiency, which ultimately leads to Reno-vascular hypertension. This work attempts to identify the localization of atherosclerotic plaque in human abdominal aorta — renal artery junction using Computational fluid dynamics (CFD).

    The atherosclerosis prone regions in an idealized human abdominal aorta-renal artery junction are identified by calculating relevant hemodynamic indicators from computational simulations using the rheologically accurate shear-thinning Yeleswarapu model for human blood. Blood flow is numerically simulated in a 3-D model of the artery junction using ANSYS FLUENT v18.2.

    Hemodynamic indicators calculated are average wall shear stress (AWSS), oscillatory shear index (OSI), and relative residence time (RRT). Simulations of pulsatile flow (f=1.25 Hz, Re = 1000) show that low AWSS, and high OSI manifest in the regions of renal artery downstream of the junction and on the infrarenal section of the abdominal aorta lateral to the junction. High RRT, which is a relative index and dependent on AWSS and OSI, is found to overlap with the low AWSS and high OSI at the cranial surface of renal artery proximal to the junction and on the surface of the abdominal aorta lateral to the bifurcation: this indicates that these regions of the junction are prone to atherosclerosis. The results match qualitatively with the findings reported in literature and serve as initial step to illustrate utility of CFD for the location of atherosclerotic plaque.

    Views (last year): 3.

Indexed in Scopus

Full-text version of the journal is also available on the web site of the scientific electronic library eLIBRARY.RU

The journal is included in the Russian Science Citation Index

The journal is included in the RSCI

International Interdisciplinary Conference "Mathematics. Computing. Education"