All issues
- 2025 Vol. 17
- 2024 Vol. 16
- 2023 Vol. 15
- 2022 Vol. 14
- 2021 Vol. 13
- 2020 Vol. 12
- 2019 Vol. 11
- 2018 Vol. 10
- 2017 Vol. 9
- 2016 Vol. 8
- 2015 Vol. 7
- 2014 Vol. 6
- 2013 Vol. 5
- 2012 Vol. 4
- 2011 Vol. 3
- 2010 Vol. 2
- 2009 Vol. 1
-
A general approach to constructing gradient methods for parameter identification based on modified weighted Gram – Schmidt orthogonalization and information-type discrete filtering algorithms
Computer Research and Modeling, 2025, v. 17, no. 5, pp. 761-782The paper considers the problem of parameter identification of discrete-time linear stochastic systems in the state space with additive and multiplicative noise. It is assumed that the state and measurements equations of a discrete-time linear stochastic system depend on an unknown parameter to be identified.
A new approach to the construction of gradient parameter identification methods in the class of discrete-time linear stochastic systems with additive and multiplicative noise is presented, based on the application of modified weighted Gram – Schmidt orthogonalization (MWGS) and the discrete-time information-type filtering algorithms.
The main theoretical results of this research include: 1) a new identification criterion in terms of an extended information filter; 2) a new algorithm for calculating derivatives with respect to an uncertainty parameter in a discrete-time linear stochastic system based on an extended information LD filter using the direct procedure of modified weighted Gram – Schmidt orthogonalization; and 3) a new method for calculating the gradient of identification criteria using a “differentiated” extended information LD filter.
The advantages of this approach are that it uses MWGS orthogonalization which is numerically stable against machine roundoff errors, and it forms the basis of all the developed methods and algorithms. The information LD-filter maintains the symmetry and positive definiteness of the information matrices. The algorithms have an array structure that is convenient for computer implementation.
All the developed algorithms were implemented in MATLAB. A series of numerical experiments were carried out. The results obtained demonstrated the operability of the proposed approach, using the example of solving the problem of parameter identification for a mathematical model of a complex mechanical system.
The results can be used to develop methods for identifying parameters in mathematical models that are represented in state space by discrete-time linear stochastic systems with additive and multiplicative noise.
-
Development of anisotropic nonlinear noise-reduction algorithm for computed tomography data with context dynamic threshold
Computer Research and Modeling, 2019, v. 11, no. 2, pp. 233-248Views (last year): 21.The article deals with the development of the noise-reduction algorithm based on anisotropic nonlinear data filtering of computed tomography (CT). Analysis of domestic and foreign literature has shown that the most effective algorithms for noise reduction of CT data use complex methods for analyzing and processing data, such as bilateral, adaptive, three-dimensional and other types of filtrations. However, a combination of such techniques is rarely used in practice due to long processing time per slice. In this regard, it was decided to develop an efficient and fast algorithm for noise-reduction based on simplified bilateral filtration method with three-dimensional data accumulation. The algorithm was developed on C ++11 programming language in Microsoft Visual Studio 2015. The main difference of the developed noise reduction algorithm is the use an improved mathematical model of CT noise, based on the distribution of Poisson and Gauss from the logarithmic value, developed earlier by our team. This allows a more accurate determination of the noise level and, thus, the threshold of data processing. As the result of the noise reduction algorithm, processed CT data with lower noise level were obtained. Visual evaluation of the data showed the increased information content of the processed data, compared to original data, the clarity of the mapping of homogeneous regions, and a significant reduction in noise in processing areas. Assessing the numerical results of the algorithm showed a decrease in the standard deviation (SD) level by more than 6 times in the processed areas, and high rates of the determination coefficient showed that the data were not distorted and changed only due to the removal of noise. Usage of newly developed context dynamic threshold made it possible to decrease SD level on every area of data. The main difference of the developed threshold is its simplicity and speed, achieved by preliminary estimation of the data array and derivation of the threshold values that are put in correspondence with each pixel of the CT. The principle of its work is based on threshold criteria, which fits well both into the developed noise reduction algorithm based on anisotropic nonlinear filtration, and another algorithm of noise-reduction. The algorithm successfully functions as part of the MultiVox workstation and is being prepared for implementation in a single radiological network of the city of Moscow.
Indexed in Scopus
Full-text version of the journal is also available on the web site of the scientific electronic library eLIBRARY.RU
The journal is included in the Russian Science Citation Index
The journal is included in the RSCI
International Interdisciplinary Conference "Mathematics. Computing. Education"




