All issues
- 2026 Vol. 18
- 2025 Vol. 17
- 2024 Vol. 16
- 2023 Vol. 15
- 2022 Vol. 14
- 2021 Vol. 13
- 2020 Vol. 12
- 2019 Vol. 11
- 2018 Vol. 10
- 2017 Vol. 9
- 2016 Vol. 8
- 2015 Vol. 7
- 2014 Vol. 6
- 2013 Vol. 5
- 2012 Vol. 4
- 2011 Vol. 3
- 2010 Vol. 2
- 2009 Vol. 1
-
Coronary arteries and angioplasty balloon mechanical behavior modeling
Computer Research and Modeling, 2026, v. 18, no. 3, pp. 589-605Тhe aim of this work is to assess the mechanical behavior of coronary vessels and angioplasty balloons during the angioplasty procedure, based on intravascular ultrasound (IVUS) and angiography data obtained for each patient individually. To treat atherosclerosis, a serious chronic inflammatory disease of the arteries characterized by the formation of atherosclerotic plaques, which causes vessel narrowing and impairs blood supply to tissues and organs, modern medical practice employs a minimally invasive endovascular procedure known as balloon angioplasty. Key aspects of modeling this procedure include understanding the behavior of patients’ arteries and the balloons used during the intervention. Based on intravascular ultrasound and angiography data, a biomechanical model of an artery affected by atherosclerosis is developed. A finite element model of the arterial segment is constructed, accounting for its nonlinear hyperelastic behavior. To simulate the behavior of the angioplasty balloon, a mathematical model of the balloon is developed and validated against experimental data. An assessment of the stress-strain state of a specific patient’s coronary artery and angioplasty balloon is performed. For a full-scale simulation of the angioplasty process, a mathematical model is developed that incorporates all three objects considered above: personalization of the artery model through the use of real patient data; a finite element model of the artery built based on of the personalized model, accounting for its nonlinear behavior; a finite element model of the angioplasty balloon. The developed mathematical models and the results obtained from them will further allow us to derive dependencies of key angioplasty parameters. These dependencies can be used to improve angioplasty techniques based on intravascular imaging data. Furthermore, the application of mathematical modeling methods will help reduce the number of clinical trials in this field.
Keywords: angioplasty, balloon, atherosclerosis, artery, mathematical modeling, intravascular imaging. -
Method for coronary blood flow velocity estimation based on angiographic images
Computer Research and Modeling, 2026, v. 18, no. 3, pp. 715-735In modern cardiology, accurate assessment of the functional significance of coronary artery stenoses is a critical factor for selecting treatment strategies and making informed clinical decisions. This paper presents an automated algorithm for processing dynamic X-ray angiographic image sequences aimed at estimating blood flow velocity. This parameter serves as the basis for determining the Quantitative Flow Ratio (QFR), which acts as an effective noninvasive alternative to traditional invasive fractional flow reserve (FFR) measurements. The proposed methodology successfully overcomes classic challenges of angiographic analysis, such as vessel motion artifacts during the cardio-respiratory cycle, variable contrast opacification, and the geometric complexity of the vascular tree in two-dimensional projections.
The presented processing workflow includes several key stages. Initially, frame preprocessing is performed to suppress noise and filter out the anatomical background. Subsequently, segmentation is implemented using a Sato filter and Otsu thresholding, followed by skeletonization to extract vessel centerlines. Particular attention is paid to the algorithm for automated identification of bifurcation points and the filtration of artifactual intersections caused by vessel overlapping. To ensure data continuity, a temporal tracking method for the target segment based on template correlation is applied, which is especially important during phases with low contrast agent concentration. The mathematical core of the algorithm is based on solving a 1D inverse problem for the advection-diffusion equation, allowing for the recovery of blood flow velocity from temporal intensity curves.
As part of the study, a detailed validation of the method was conducted by comparing automated calculation results with manual expert measurements across ten clinical datasets. The results confirm the robustness of the computational scheme within physiologically relevant ranges and its ability to significantly reduce inter-observer variability. The developed approach minimizes the need for physician intervention in the data processing stage, opening up prospects for creating real-time clinical decision support systems in the catheterization laboratory setting.
Indexed in Scopus
Full-text version of the journal is also available on the web site of the scientific electronic library eLIBRARY.RU
The journal is included in the Russian Science Citation Index
The journal is included in the RSCI
International Interdisciplinary Conference "Mathematics. Computing. Education"